Assist 4D probe; acknowledge the probe by means of the ID code; switch the 4D push sign by way of the  electrical relay to create the 4D probe do the job Generally. four.two.2 Key board The principle board could be divided into two components: front-stop of the primary board and back again-stop of the most crucial board.

Cookie penting untuk memfungsikan situs dengan semestinya. Untuk meningkatkan pengalaman Anda, kami menggunakan cookie untuk mengingat detail login Anda dan menyediakan login aman, mengumpulkan statistik untuk mengoptimalkan fungsionalitas situs, dan menyediakan konten yang disesuaikan dengan minat Anda.

Get a complete and prolonged see from the anatomical composition by panoramic imaging coupled with velocity sign and ahead/backward scan capability building scanning much simpler, smoother and even more controllable.

Tend not to use any cables besides the cables delivered With all the product by Mindray. 3. Utilize the cable presented with This technique to attach the printer. Other cables might lead to electrical shock. Web page 15: Mechanical Safety

Cut off cable ties connecting the principle unit within the Display screen by diagonal cutting pliers, and then pull out the corresponding cable plugs.

Mindray’s new era of black & white ultrasound process, DP-50 Professional, is provided with Innovative imaging technologies enabling further penetration and a lot quicker impression acquisition with better resolution.

Page one hundred forty five Cleanse user interface Equipment: dry tender cloth, gentle soapy drinking water  Process:  Use dry gentle fabric to wash the floor on the system. In case the process is soiled, moisten the smooth fabric with delicate soapy drinking water and wipe off any stains. Use dry comfortable cloth to remove any moisture and allow all tricky surfaces to completely air-dry. Page 146: Clean up The Peripherals

Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi element mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.

Permits use of several scanned angles to variety just one graphic, resulting in Increased distinction resolution and enhanced visualization

five.2.3 Geometric positioning accuracy Longitudinal geometric positioning precision  Take a look at Action: Do adjustments as the way in which in testing the most depth. Report the gap by 20mm Each and every segment on the longitudinal targets line utilizing the measurement caliper; Pick out the value with the Dp50rb login greatest error (to 20mm), determine the precision using the components underneath The measurement caliper really should be positioned within the upper fringe of the goal, NOTE:... Web site 79 Transverse geometric positioning precision  Test Move: Deal with the scan surface from the phantom with water or couple gel, Carefully contact the probe While using the scan surface area Change the depth, producing the transverse targets being displayed while in the graphic. Adjust the main target stage to be posited beside the transverse targets (the typical is just not very clear) Regulate parameters like acquire, TGC, building Just about every transverse targets to become Plainly shown. Web page eighty 5.5.2.four Blackout Area Examination Move: Protect the scan surface with the phantom with water or couple gel, gently Speak to the probe Together with the scan floor Alter the depth at a reduced worth, and set the main target at the closest place to the scan surface area. Minimize the value of parameters like AP, Get right up until the history sounds just is often viewed. Website page 81: Software package Enhance And Servicing

The DP-50 Qualified is an modern, superior-effectiveness Ultrasound Procedure engineered to help you obtain the insights you need. The Process’s highly effective motor and superior-speed processing offer exceptional picture good quality and a whole data management Answer.

.. Page 161 The indicator within the printer Glitches come about if the adapter turns orange, and the printing printer adapter operates. Disconnect and join the fails. energy adapter, electrical power to the printer adapter all over again, and confirm whether the printing is regular following one moment. Web site 163: Electrical Basic safety Inspection

Be aware: Prior to inserting the connector into the probe port, inspect the connector pin. If the pin is bent, never make use of the probe until finally it's been inspected / repaired / replaced. Installing Peripherals For the products of your supported peripherals, you should confer with “two.

Mindray respects your privateness. We use cookies for several different applications, which include Web page features, enhancing your encounter of our website, building integration with social networking and serving to concentrate on our marketing.

Take note: Make certain that you may pull out and force into the IO board sockets vertically when pulling out and assembling the IO board assembly about the position from the cope with. Eliminate panhead screws with washers M3X6 (4) used to safe the IO board, and afterwards you might take out the IO board. Site 116 Take away panhead screws with washers (2 M3X6) which happen to be set on the most crucial device, take out the upper baffle after which you can pull out two cables connecting the key board to the power module assembly.

Report this page